43
9500+ SCPI Command Summary
Keyword
Lower-Level
Keyword
Lower-Level
Keyword
Parameter
Std /
New
Comments
:SPULSe Std
Subsystem. Contains commands to control
the output pulse generation. Commands
without suffix refer to the currently selected
logical instrument. See INSTrument
:STATe 0 / 1 or OFF / ON Std
Enables / Disables the output for all
channels. Command is the same as pressing
the RUN / STOP button.
:PERiod 0.0000002s - 5000s Std
Sets the T
0
period.
:MODe
NORMal / SINGle /
BURSt / DCYCle
New
Sets the T
0
mode.
:BCOunter 1 - 1000000 New
Burst Counter. Sets the number of pulses to
generate when in burst mode.
:PCOunter 1 - 1000000 New
Pulse Counter. Sets the number of pulses to
generate during the on cycle of the Duty
Cycle mode.
:OCOunter 1 - 1000000 New
Off Counter. Number of pulses to inhibit
output during the off cycle of the Duty Cycle
mode.
:EXTernal New
Subsystem. Contains the commands to
define the system use of the external input.
:MODe
DISabled / TRIGger
/ GATe
New
Selects the trigger mode.
:LEVel 0.20 - 15 New
Sets the trigger threshold. Value is in volts,
with a range of 0.20 to 15 Volts.
:EDGe RISing / FALLing New
Selects which edge (rising of falling) to use
as the trigger signal.
:POLarity LOW / HIGH New
Sets the POLarity of the gate signal. HIGH
output is active when the gate signal is high.
LOW output is active when the gate signal is
Komentarze do niniejszej Instrukcji